DPS SERIES PWM AC POWER SUPPLY

 

 

Power capacity

Output Voltage

Stability of voltage

Accuracy of Voltmeter and amperemeter

Accuracy of power meter

Maximum output current

frequency of output voltage

Stability of frequency

Total harmonic distortion

Efficiency

Load regulation rate

Source voltage effect

Self-protection function

 

Power capacity

Output Voltage

Stability of voltage

Accuracy of Voltmeter and amperemeter

Accuracy of power meter

Maximum output current

frequency of output voltage

Stability of frequency

Total harmonic distortion

Efficiency

Load regulation rate

Source voltage effect

Self-protection function

 

Power capacity

Output Voltage

Stability of voltage

Accuracy of Voltmeter and amperemeter

Accuracy of power meter

Maximum output current

frequency of output voltage

Stability of frequency

Total harmonic distortion

Efficiency

Load regulation rate

Source voltage effect

Self-protection function

 

Power capacity

Output Voltage

Stability of voltage

Accuracy of Voltmeter and amperemeter

Accuracy of power meter

Maximum output current

frequency of output voltage

Stability of frequency

Total harmonic distortion

Efficiency

Load regulation rate

Source voltage effect

Self-protection function

 

Power capacity

Output Voltage

Stability of voltage

Accuracy of Voltmeter and amperemeter

Accuracy of power meter

Maximum output current

frequency of output voltage

Stability of frequency

Total harmonic distortion

Efficiency

Load regulation rate

Source voltage effect

Self-protection function

DPS1005

500VA

0~150V; 0~300V

≤0.2%

±(0.4%reading+0.1%range+1digit)

±[0.4%reading+(0.1/PF)%range+1digit]

110V/4.6A, 220V/2.3A

40.0Hz~65.0Hz;40.0Hz~450Hz(optional)

≤0.03%reading+1digit

≤0.5%( 40.0Hz~65.0Hz)

≥75%

≤0.2%

≤0.1%

Protection for short-circuit, over-current, over-load, over-heated.

DPS1010

1KVA

0~150V; 0~300V

≤0.2%

±(0.4%reading+0.1%range+1digit)

±[0.4%reading+(0.1/PF)%range+1digit]

"110V/9.2A, 220V/4.6A " 40.0Hz~65.0Hz;

40.0Hz~450Hz(optional)

≤0.03%reading+1digit

≤0.5%( 40.0Hz~65.0Hz)

≥80%

≤0.2%

≤0.1%

Protection for short-circuit, over-current, over-load, over-heated.

DPS1020

2KVA

0~150V; 0~300V

≤0.2%

±(0.4%reading+0.1%range+1digit)

±[0.4%reading+(0.1/PF)%range+1digit]

110V:18.4A; 220V:9.2A

40.0Hz~65.0Hz;40.0Hz~450Hz(optional)

≤0.03%reading+1digit

≤0.5%( 40.0Hz~65.0Hz)

≥80%

≤0.2%

≤0.1%

Protection for short-circuit, over-current, over-load, over-heated.

DPS1030

3KVA

0~150V; 0~300V

≤0.2%

±(0.4%reading+0.1%range+1digit)

±[0.4%eading+(0.1/PF)%range+1digit)

110V:27A; 220V:13.5A

45.0Hz~65.0Hz; 45.0Hz~400Hz(Optional)

≤0.03%

≤2%

≥85%

"0.2%V0+0.1V (V0:half-load output voltage) "

≤0.1%

Protection for short-circuit, over-current, over-load, over-heated.

DPS1060

6KVA

0~150V; 0~300V

≤0.2%

±(0.4%reading+0.1%range+1digit)

±[0.4%eading+(0.1/PF)%range+1digit)

110V:54A; 220V:27A

45.0Hz~65.0Hz; 45.0Hz~400Hz(Optional)

≤0.03%

≤2%

≥85%

"0.2%V0+0.1V (V0:half-load output voltage) "

≤0.1%

Protection for short-circuit, over-current, over-load, over-heated.